Add pm7250b pmic alarm sensor and bcl sensors thermal zone mitigations for khaje. Disable cx ipeak device for khaje. Change-Id: I3d7accd84757f82791e26f35f94379adc1b41265
117 lines
2.0 KiB
Devicetree
117 lines
2.0 KiB
Devicetree
#include <dt-bindings/thermal/thermal.h>
|
|
|
|
&thermal_zones {
|
|
pm7250b-tz {
|
|
cooling-maps {
|
|
trip0_bat {
|
|
trip = <&pm7250b_trip0>;
|
|
cooling-device =
|
|
<&pm7250b_charger (THERMAL_MAX_LIMIT-1)
|
|
(THERMAL_MAX_LIMIT-1)>;
|
|
};
|
|
|
|
trip1_bat {
|
|
trip = <&pm7250b_trip1>;
|
|
cooling-device =
|
|
<&pm7250b_charger THERMAL_MAX_LIMIT
|
|
THERMAL_MAX_LIMIT>;
|
|
};
|
|
};
|
|
};
|
|
|
|
soc {
|
|
cooling-maps {
|
|
soc_cpu4 {
|
|
trip = <&soc_trip>;
|
|
cooling-device = <&cpu4_isolate 1 1>;
|
|
};
|
|
|
|
soc_cpu5 {
|
|
trip = <&soc_trip>;
|
|
cooling-device = <&cpu5_isolate 1 1>;
|
|
};
|
|
|
|
soc_cpu6 {
|
|
trip = <&soc_trip>;
|
|
cooling-device = <&cpu6_isolate 1 1>;
|
|
};
|
|
|
|
soc_cpu7 {
|
|
trip = <&soc_trip>;
|
|
cooling-device = <&cpu7_isolate 1 1>;
|
|
};
|
|
};
|
|
};
|
|
|
|
pm7250b-bcl-lvl0 {
|
|
cooling-maps {
|
|
lbat0_cpufreq4 {
|
|
trip = <&b_bcl_lvl0>;
|
|
cooling-device =
|
|
<&CPU4 (THERMAL_MAX_LIMIT-4)
|
|
(THERMAL_MAX_LIMIT-4)>;
|
|
};
|
|
|
|
lbat0_cpu6 {
|
|
trip = <&b_bcl_lvl0>;
|
|
cooling-device = <&cpu6_isolate 1 1>;
|
|
};
|
|
|
|
lbat0_cpu7 {
|
|
trip = <&b_bcl_lvl0>;
|
|
cooling-device = <&cpu7_isolate 1 1>;
|
|
};
|
|
|
|
lbat0_gpu {
|
|
trip = <&b_bcl_lvl0>;
|
|
cooling-device = <&msm_gpu 2 2>;
|
|
};
|
|
|
|
lbat0_cdsp {
|
|
trip = <&b_bcl_lvl0>;
|
|
cooling-device = <&cdsp_sw 2 2>;
|
|
};
|
|
};
|
|
};
|
|
|
|
pm7250b-bcl-lvl1 {
|
|
cooling-maps {
|
|
lbat1_cpu4 {
|
|
trip = <&b_bcl_lvl1>;
|
|
cooling-device = <&cpu4_isolate 1 1>;
|
|
};
|
|
|
|
lbat1_cpu5 {
|
|
trip = <&b_bcl_lvl1>;
|
|
cooling-device = <&cpu5_isolate 1 1>;
|
|
};
|
|
|
|
lbat1_gpu {
|
|
trip = <&b_bcl_lvl1>;
|
|
cooling-device = <&msm_gpu 4 4>;
|
|
};
|
|
|
|
lbat1_cdsp {
|
|
trip = <&b_bcl_lvl1>;
|
|
cooling-device = <&cdsp_sw 4 4>;
|
|
};
|
|
};
|
|
};
|
|
|
|
pm7250b-bcl-lvl2 {
|
|
cooling-maps {
|
|
lbat2_gpu {
|
|
trip = <&b_bcl_lvl2>;
|
|
cooling-device = <&msm_gpu THERMAL_MAX_LIMIT
|
|
THERMAL_MAX_LIMIT>;
|
|
};
|
|
|
|
lbat2_cdsp {
|
|
trip = <&b_bcl_lvl2>;
|
|
cooling-device = <&cdsp_sw THERMAL_MAX_LIMIT
|
|
THERMAL_MAX_LIMIT>;
|
|
};
|
|
};
|
|
};
|
|
};
|